Overview
A certificate of analysis (COA) documents the test results for a specific batch and compares them with the defined specifications. It links the physical material to its analytical data via the batch number. A COA applies only to the batch named in it.
Scientific background
Purpose
A COA answers the question of whether a specific batch meets the requirements set for it. It is issued by the manufacturer’s quality control department or by a contracted testing laboratory. Unlike a general product data sheet, it contains measured results rather than typical values. For research it is therefore a key document for traceability: it records the analytical basis on which a material was used.
Typical structure
- Header: issuing body, document number, date of issue.
- Identification: product name, sequence, molecular formula, molecular weight and, where applicable, salt form and CAS number.
- Batch details: batch number, dates of manufacture and testing, retest or expiry date.
- Test table: for each test item, the method, the specification (acceptance criterion) and the result with its unit.
- Assessment: a statement of whether the batch meets the specification.
- Release: name, position and signature of the responsible person.
- Attachments: often chromatograms and mass spectra as excerpts of the raw data.
Common tests for peptides
The standard set includes appearance, identity (usually by mass spectrometry: measured versus calculated mass) and chromatographic purity (HPLC). Depending on requirements, peptide content, water content (Karl Fischer titration), counterion content, endotoxins, residual solvents or heavy metals may be added. Which tests were carried out can be seen only from the document itself – anything not listed was not tested.
What to check when reading one
- Does the batch number match the label?
- Is the method stated for every result?
- Are result and specification given in the same unit, and is the specification met?
- Are the dates plausible – is the test date after the date of manufacture, for example?
- Who carried out the testing, and who released the batch?
What a COA is not
A COA is not a safety data sheet: it contains no information on hazards, protective measures or disposal. Nor is it a statement about suitability for a particular experiment. It shows only which results the named batch achieved in the tests listed.
Molecular data
No molecular data is recorded for this entry.
State of research
For medicinal products and active substances, GMP regulations specify what a certificate of analysis must contain; ICH guideline Q7 for active pharmaceutical ingredients devotes a separate section to the subject. For research chemicals there is no binding uniform standard, which is why the scope and level of detail of COAs vary considerably between suppliers.
Sources
The sources for this entry are currently being verified by the editorial team and will appear once verified.
Safety and research notes
- A COA does not replace the safety data sheet; the safety data sheet is authoritative for handling, protective equipment and disposal.
- The results apply only to the batch named.
- Archive the COA and batch number together with the experimental data so that results remain traceable later.
- For research use only. Not for use in humans or animals.