Overview

Mass spectrometry determines the mass-to-charge ratio (m/z) of ionised molecules. In peptide analysis it is used primarily to confirm the identity of a substance via its molecular mass. Fragmentation experiments can also yield sequence information.

Scientific background

How it works

Every mass spectrometer comprises three units: an ion source that converts molecules into charged particles, a mass analyser that separates these ions by m/z, and a detector. The analyser and detector operate under high vacuum so that the ions do not collide with gas molecules. The result is a mass spectrum: signal intensity plotted against m/z.

Soft ionisation

For a long time, large and thermally sensitive biomolecules could hardly be ionised intact. That changed at the end of the 1980s with two ‘soft’ techniques. In electrospray ionisation (ESI), ions are formed directly from a solution, which makes coupling with liquid chromatography possible. In matrix-assisted laser desorption/ionisation (MALDI), the sample is co-crystallised with a light-absorbing matrix and transferred into the gas phase by a laser pulse; MALDI produces predominantly singly charged ions. John B. Fenn and Koichi Tanaka shared the 2002 Nobel Prize in Chemistry for developing soft desorption and ionisation methods.

Isotope patterns and mass definitions

Natural carbon contains about 1.1 % of the isotope ¹³C. In a high-resolution spectrum a peptide therefore appears not as a single line but as an isotope pattern. The peak containing only the lightest isotope of each element corresponds to the monoisotopic mass; the weighted average of all isotopologues corresponds to the average mass. Any mass comparison must make clear which of the two is meant.

Tandem mass spectrometry

In MS/MS experiments a specific ion is isolated and fragmented by collisions with gas molecules. Peptides break preferentially at their peptide bonds; the resulting fragment series (b and y ions) differ by the masses of individual amino acid residues, so the sequence can be read in full or in part.

What a result shows

A mass match shows that a substance corresponds to the expected molecular formula. It does not show that the sample is pure, and it does not distinguish between isomers of the same mass. In peptide quality control, MS is therefore combined with a chromatographic purity determination.

Molecular data

No molecular data is recorded for this entry.

State of research

Mass spectrometry is now standard in peptide and protein analysis. Further development focuses on higher resolution and sensitivity, ion mobility as an additional separation dimension and top-down methods in which intact proteins are fragmented. The papers on ESI (Fenn et al., 1989) and MALDI (Karas and Hillenkamp, 1988) are regarded as the foundational work on the two soft ionisation techniques.

Sources

The sources for this entry are currently being verified by the editorial team and will appear once verified.

Safety and research notes

  • Mass spectrometers operate with high voltage, vacuum pumps and compressed gases; maintenance should be carried out only by trained staff following the manufacturer’s instructions.
  • MALDI instruments contain laser sources; never bypass protective interlocks.
  • MALDI matrices and solvents can be irritant or flammable – consult the safety data sheets and wear safety glasses and gloves.
  • Dispose of sample residues and contaminated consumables in accordance with local regulations.